<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Engine Monitoring  - J2K100  </title>
<link>https://maretron.com/wp-content/phpkbv96/category.php?id=15</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB (https://www.phpkb.com)</description>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=556</guid>
										<title>How do I perform J2K100 quick setup using the N2KAnalyzer program?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=556</link>
										<description><![CDATA[Refer to this article&nbsp;for help on setting up your first J2K100 especially&nbsp;when connected to the following engine manufacturers J1939 networks: Caterpillar, John Deere, Cummins, Steyr, ECU&nbsp;Delphi Mefi 4-6, Crusader, MAN, Detroit Diesel,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=306</guid>
										<title>Does Maretron have a interface cable for Caterpillar engine networks to the J2K100 device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=306</link>
										<description><![CDATA[The MCF-2M-D12CAT cable is used to interface a J2K100 to a CAT marine power display. It is recommended that the MCF-2M-D12CAT cable should connect to one of two ports on the CAT display. The ideal connection should be the occupied twelve pin...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=468</guid>
										<title>What type of information can be viewed on Maretron`s display products, and what products are required to generate the data to be displayed?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=468</link>
										<description><![CDATA[The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder.&nbsp; To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=451</guid>
										<title>How do I determine whether the J2K100 is compatible with my Caterpillar engines?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=451</link>
										<description><![CDATA[Most Caterpillar engines may have J1939 on production years 1996 and beyond. A person who installs a J2K100 must do a visual assessment of the existing J1939 engine connections or contact a Caterpillar representative for guidence.&nbsp; &nbsp; Here...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=544</guid>
										<title>What marine engines are found to have J1939 capability?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=544</link>
										<description><![CDATA[Following is a table showing engines and their J1939 capability.&nbsp; &nbsp;Engine manufacturer&nbsp; &nbsp;Controller Module &nbsp;J1939 Capable standard? Must Be Ordered With J1939 Capabilities. &nbsp;Caterpillar&nbsp;&nbsp; &nbsp;ADEM III and A4...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=439</guid>
										<title>What are the voltage specifications for each Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=439</link>
										<description><![CDATA[Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface CLM100 P/N: M000070&nbsp; Current Loop Monitor 9 to 32 Volts &nbsp; SSC200 P/N: M000001, M000021, M000022 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts &nbsp;...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=536</guid>
										<title>Do gasoline engines with an electronic control module (ECM) have J1939 compatibilities?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=536</link>
										<description><![CDATA[Most Gasoline engines come equipped with a standard ECM which communicates the J1939 protocol.  One of the most common ECMs found today on many gasoline engines happens to be manufactured by Delphi and is commonly called MeFi.  This particular ECM...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=613</guid>
										<title>Can Maretron devices be displayed on a Raymarine Seatalk NG network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=613</link>
										<description><![CDATA[Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=374</guid>
										<title>Using N2KAnalyzer, how do I recover  a Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=374</link>
										<description><![CDATA[Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems. A Maretron device that is&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=674</guid>
										<title>Can the J2K100 convert Volvo-Penta engine data to NMEA2000?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=674</link>
										<description><![CDATA[Yes, a J2K100 can be used to convert a Volvo Penta standard J1939 messages to NMEA2000. &nbsp;Prior to a purchase of a J2K100(Per engine) examine the existing cabling provided by the engine manufacturer.&nbsp; Engines with EVC, EDC systems can be...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=563</guid>
										<title>Can a J2K100 connect to a John Deere J1939 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=563</link>
										<description><![CDATA[Yes, the J2K100 can easily be integrated to a John Deere J1939 network. Exact locations where the J2K100 will connect to the network may vary. &nbsp;Find the Helm engine display and locate the Deutsch connector labeled "Engine ECU". The connector is...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=506</guid>
										<title>Can the J2K100 connect to a Cummins engine?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=506</link>
										<description><![CDATA[The J2K100 can be connected to a Cummins Vessel Integration Panel via the J1939 diagnostic port located on the panel itself. Please review the image posted below. Additional non-Maretron parts will be needed to complete the connections to the panel ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=219</guid>
										<title>How is J1939 different from NMEA 2000?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=219</link>
										<description><![CDATA[J1939 and NMEA 2000 networks are both based on the same hardware (Controller Area Network (CAN)), and both protocols use the same message format (the messages are actually compatible and can coexist on the same network), however, NMEA uses different...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=673</guid>
										<title>Can Maretron`s sensor data be displayed on a Garmin network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=673</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Garmin displays with &ldquo;NMEA 2000&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=566</guid>
										<title>How do I connect the J2K100 to a MAN CLC 6.3 or 6.5 engine display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=566</link>
										<description><![CDATA[The J2K100 has a compatible connection to the MAN engine interface found on the engine interface port of most MAN CLC6.3-6.5 engine displays.  We have observed that our customers interface the J2K100 in parallel to the display using a standard micro...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=558</guid>
										<title>How do I make a custom NMEA 2000 cordset cable? Does Maretron offer a field attachable connector?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=558</link>
										<description><![CDATA[Maretron offers several accessories that allow you to make a custom NMEA 2000 cable.It may be necessary to make a custom cable for the following reasons: Cable runs longer than 10m in length Routing raw cables micro/mid through bulkheads, wire trays,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=672</guid>
										<title>Can Maretron`s sensor data be displayed on a Furuno CANBUS network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=672</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Furuno displays with &ldquo;CANBUS&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp;specifically,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=604</guid>
										<title>Can the J2K100 connect to third party protocol converters that support J1708 or J1587?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=604</link>
										<description><![CDATA[Maretron's J2K100 attaches directly into J1939 networks of compatible engines, transmissions, and gensets and converts the J1939 data to NMEA 2000. For engines that offer protocols such as J1708 or J1587, users may choose to translate the engine's...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=626</guid>
										<title>Is the the J2K100 compaible with Crusader engines?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=626</link>
										<description><![CDATA[The J2K100 can connect to a Crusader diagnostic CANBUS port for J1939 operations. Crusader offers service manuals&nbsp;for several supported engines. Maretron suggests consulting with your engine technician or contacting crusader direct for suggested...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=702</guid>
										<title>Duel/Split Screen Engine Display template for TSMxxx/MBBxxx</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=702</link>
										<description><![CDATA[Below are sample images of the attached .nvs screen files. Port Engine 1 &amp; Stbd Engine 1 .nvs files  &nbsp; Port Engine 2 &amp; Stbd Engine 2 .nvs  &nbsp; &nbsp; How to load screens onto TSMxxx/MBBxxx or PC running N2KView. Copy the .nvs (Screen...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=627</guid>
										<title>I would like to see NMEA2000 Engine and Transmission warnings on my N2K network, what J1939 diagnostic codes will the J2K100 convert?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=627</link>
										<description><![CDATA[The J2K100 will convert J1939 Diagnostic SPN/PGNs to NMEA2000 Engine and&nbsp;Transmission Warning messages. Consult the engine manufacturer to determine if an engine will transmit these messages over the NMEA2000 bus. The following table (figure 1)...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=662</guid>
										<title>How do I connect the Dometic Q-logic controller to the J2K100 for N2KView control?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=662</link>
										<description><![CDATA[Please be advised, some Dometic controller modules will require the user to enable the CAN (J1939) output allowing the J2K100 to detect the signal.  Please locate the Q-logic controller module and the J1939 interface connections. Figure 1 illustrates...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=706</guid>
										<title>Does Maretron offer quick setup instructions for a dual J2K100 setup?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=706</link>
										<description><![CDATA[Does Maretron offer quick setup instructions for a dual J2K100 setup? Refer to this article&nbsp;for help on setting up your J2K100s especially&nbsp;when connected to the following engine manufacturers J1939 networks: Caterpillar, John Deere, Cummins...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=586</guid>
										<title>What information is available from the J1939 to NMEA 2000 Bridge (J2K100) and can be viewed on Maretron`s displays?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=586</link>
										<description><![CDATA[&nbsp;The J2K100 is capable of transmitting the following information: PGN 65030 AC Generator Current AC Generator Frequency AC Generator Voltage  Engine parameters 127488, 127489 Tachometer Engine Hours Coolant Pressure Coolant Water Temperature...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=260</guid>
										<title>I have an Onan generator with a power rating between 40-99kW; what Maretron adapter cable should I order to connect the generator to the J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=260</link>
										<description><![CDATA[You should order the Maretron adapter cable MCF-2M-D4 (J2K100 adapter Micro female to Deutsch 4 Pin 2 Meter Cordset) when connecting an Onan generator with a power rating of 40-99kW to the J2K100.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=419</guid>
										<title>What firmware changes have taken place on the Maretron J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=419</link>
										<description><![CDATA[What firmware changes have taken place on the Maretron J2K100?Â  Update your device using a Maretron gateway, USB100 or IPG100, paired with a Windows PC running N2KAnalyzer.  Â  2.4.2.1 (2024-05-08)  Support SPN selection for 127493 Transmission oil...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=231</guid>
										<title>How do I display the J2K100 engine hours on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=231</link>
										<description><![CDATA[You display the J2K100 engine hours on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the hours and press enter....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=226</guid>
										<title>How do I display the J2K100 engine oil pressure on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=226</link>
										<description><![CDATA[You display the J2K100 engine oil pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil pressure and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=230</guid>
										<title>How do I display the J2K100 engine fuel rate on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=230</link>
										<description><![CDATA[You display the J2K100 engine fuel rate on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the fuel rate and press...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=227</guid>
										<title>How do I display the J2K100 engine oil temperature on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=227</link>
										<description><![CDATA[You display the J2K100 engine oil temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil temperature...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=235</guid>
										<title>How do I display the J2K100 transmission gear on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=235</link>
										<description><![CDATA[You display the J2K100 transmission gear on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the gear and press enter....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=245</guid>
										<title>How do I set the J2K100 configuration setting called &quot;NMEA 2000 Engine Instance:&quot; using Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=245</link>
										<description><![CDATA[You set the J2K100 configuration setting called "NMEA 2000 Engine Instance:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=225</guid>
										<title>How do I display the J2K100 engine boost pressure on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=225</link>
										<description><![CDATA[You display the J2K100 engine boost pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the boost pressure and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=247</guid>
										<title>How do I set the J2K100 configuration setting called &quot;NMEA 2000 Transmission Instance:&quot; using Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=247</link>
										<description><![CDATA[You set the J2K100 configuration setting called "NMEA 2000 Transmission Instance:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?"...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=635</guid>
										<title>I have a STEYR Engine connected to a STEYR Control Center SCC, What cable should be used to connect the J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=635</link>
										<description><![CDATA[The STEYR SCC system is J1939 compatible to a J2K100. Use the MCF-2M-D4 cable as a connection to a single or dual J2K100 segment for engine system conversion.&nbsp; The MCF-2M-D4 can be connected to an unused panel mating connection originating from...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=233</guid>
										<title>How do I display the J2K100 engine fuel pressure on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=233</link>
										<description><![CDATA[You display the J2K100 engine fuel pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the fuel pressure and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=259</guid>
										<title>I have an Onan generator with a power rating between 4-32kW; what Maretron adapter cable should I order to connect the generator to the J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=259</link>
										<description><![CDATA[The Maretron adapter cable MCF-2M-D12 (J2K100 adapter Micro female to Deutsch 12 Pin 2 Meter Cordset) connects an Onan generator with a power rating of 4-32kW to the J2K100.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=232</guid>
										<title>How do I display the J2K100 engine coolant pressure on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=232</link>
										<description><![CDATA[You display the J2K100 engine coolant pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the coolant pressure...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=239</guid>
										<title>How do I display the J2K100 generator average line-neutral AC RMS voltage on Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=239</link>
										<description><![CDATA[You display the J2K100 generator average line-neutral AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=237</guid>
										<title>How do I display the J2K100 transmission oil temperature on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=237</link>
										<description><![CDATA[You display the J2K100 transmission oil temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=238</guid>
										<title>How do I display the J2K100 generator average line-line AC voltage on Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=238</link>
										<description><![CDATA[You display the J2K100 generator average line-line AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=236</guid>
										<title>How do I display the J2K100 transmission oil pressure on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=236</link>
										<description><![CDATA[You display the J2K100 transmission oil pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil pressure...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=240</guid>
										<title>How do I display the J2K100 generator average AC frequency on Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=240</link>
										<description><![CDATA[You display the J2K100 generator average AC frequency on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the frequency...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=228</guid>
										<title>How do I display the J2K100 engine coolant temperature on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=228</link>
										<description><![CDATA[You display the J2K100 engine coolant temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the coolant...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=252</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;Reset Factory Defaults&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=252</link>
										<description><![CDATA[Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "Reset Factory Defaults" which is used to return the J2K100 to its factory settings. Resetting the J2K100 to factory defaults sets the J1939 source address back...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=241</guid>
										<title>How do I display the J2K100 generator average AC current on Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=241</link>
										<description><![CDATA[You display the J2K100 generator average AC current on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the current and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=234</guid>
										<title>How do I display the J2K100 engine percent load on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=234</link>
										<description><![CDATA[You display the J2K100 engine percent load on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the percent load and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=250</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;NMEA 2000 PGN Enable/Disable...&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=250</link>
										<description><![CDATA[Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 PGN Enable/Disable?" which is used to turn on and off specific messages that are transmitted by the J2K100.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=243</guid>
										<title>How do I set the J2K100 configuration setting called &quot;J1939 Source Address:&quot; using Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=243</link>
										<description><![CDATA[You set the J2K100 configuration setting called "J1939 Source Address:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=248</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;J1939 Diagnostic Messages:&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=248</link>
										<description><![CDATA[Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "J1939 Diagnostic Messages:"&nbsp; which is used to configure the J2K100 to pass diagnostic messages from the J1939 network through to the NMEA 2000 network....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=251</guid>
										<title>Is it possible to turn on or off J2K100 NMEA 2000 transmitted messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=251</link>
										<description><![CDATA[Yes, it is possible to turn on and off the J2K100 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display. On the display, enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=220</guid>
										<title>Is J1939 similar to NMEA 2000 in that the J1939 network requires terminators?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=220</link>
										<description><![CDATA[Yes, J1939 and NMEA 2000 both use CAN technology where network topology requires terminators on both ends of the trunk or backbone. Please refer to the application note entitled, "Interfacing J1939 Engines and/or Gensets to an NMEA 2000&reg; Network...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=253</guid>
										<title>How do I reset the J2K100 to send the factory default NMEA 2000 messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=253</link>
										<description><![CDATA[You reset the J2K100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=249</guid>
										<title>How do I set the J2K100 configuration setting called &quot;J1939 Diagnostic Messages:&quot; using Maretron`s DSM150 or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=249</link>
										<description><![CDATA[You set the J2K100 configuration setting called "J1939 Diagnostic Messages:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=267</guid>
										<title>On which Onan generators is the J1939 interface offered as an option?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=267</link>
										<description><![CDATA[Onan generators with power ratings from 4-32 kW offer the J1939 interface as an option.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=255</guid>
										<title>Which Onan generators come standard with a J1939 interface?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=255</link>
										<description><![CDATA[Onan generators with power ratings from 40-99 kW offer the J1939 interface as standard equipment.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=257</guid>
										<title>If I use the J2K100 with my Onan generator that has a power rating between 4-32kW, what data can I expect to see on the NMEA 2000 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=257</link>
										<description><![CDATA[The J2K100 provides the following information when hooked to an Onan generator with a power rating of 4-32KW: Generator Average Line-Neutral AC RMS Voltage Generator Average AC RMS Frequency Engine Coolant Temperature Engine Oil Pressure Battery...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=217</guid>
										<title>What is J1939?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=217</link>
										<description><![CDATA[J1939 is a Society of Automotive Engineers (SAE) networking standard that is similar to NMEA 2000. Both network protocol standards are based on the same hardware called Controller Area Network (CAN) and both protocols use the same message format. The...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=216</guid>
										<title>What is a J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=216</link>
										<description><![CDATA[The J2K100 is a gateway or bridge between a J1939 network and an NMEA 2000 network. The J2K100 receives messages (or PGNs) from a J1939 network and converts the messages into NMEA 2000 messages (or PGNs). In some cases, J1939 messages are the same as...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=266</guid>
										<title>How many J2K100s do I need if I have two engines and I would like convert the J1939 information from both engines to NMEA 2000?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=266</link>
										<description><![CDATA[You need one J2K100 per engine. If you have two engines with J1939 interfaces, you would need two J2K100s to convert the information from both engines to NMEA 2000.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=415</guid>
										<title>What are the basic configurable parameters for a J2K100 and how do I configure them using a DSM250?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=415</link>
										<description><![CDATA[...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=224</guid>
										<title>How do I display the J2K100 engine speed or tachometer on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=224</link>
										<description><![CDATA[You display the J2K100 tachometer on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press  Scroll to the favorite screen where you would like to view the tachometer and press  Scroll to ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=264</guid>
										<title>Which engines and generators work with the J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=264</link>
										<description><![CDATA[The J2K100 works with any engine or generator that has a J1939 interface. Most modern marine engines over 150 HP (112 kW) have a J1939 interface. Please contact your engine or generator manufacturer or distributor to understand whether your engine or...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=222</guid>
										<title>What information does the J2K100 provide over the NMEA 2000 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=222</link>
										<description><![CDATA[As long as the engine or generator is providing the appropriate information via the J1939 interface, the J2K100 is capable of producing the following NMEA 2000 information: engine speed (tachometer) engine boost pressure engine oil pressure engine...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=261</guid>
										<title>Why doesn`t the J2K100 work with some versions of Onan generators?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=261</link>
										<description><![CDATA[Some of Onan's early generators using the J1939 Network Interface Module (NIM) used ceramic resonators as opposed to crystal oscillators for the clock or timing source. Since the ceramic resonators are not as accurate or stable as crystal oscillators...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=246</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;NMEA 2000 Transmission Instance:&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=246</link>
										<description><![CDATA[Maretron's DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 Transmission Instance:" which is used to program the J2K100 to transmit the appropriate NMEA 2000 instance. For example, if the J2K100 is connected...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=459</guid>
										<title>Who makes J1939 connectors?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=459</link>
										<description><![CDATA[
A predominant manufacturer of J1939 connectors is Deutsch Industrial. Please see the attached document entitled "Deutsch Controller Area Network Series Technical Manual" for more information.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=254</guid>
										<title>Can I use the J2K100 together with Onan generators?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=254</link>
										<description><![CDATA[Yes, you can use the J2K100 together with Onan generators. Some of Onan generators (40-99kW) come standard with an J1939 interface,&nbsp; while others (4-32kW) offer the J1939 interface as an option.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=221</guid>
										<title>Where would I use a J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=221</link>
										<description><![CDATA[You use the J2K100 if you have a propulsion engine or a generator that has a J1939 network connection and you want to display engine or electrical information on an NMEA 2000 compatible display.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=218</guid>
										<title>I know the J2K100 receives messages from the J1939 network and subsequently transmits them over the NMEA 2000 network, but does the J2K100 transmit any messages on the J1939 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=218</link>
										<description><![CDATA[By default, the J2K100 transmits no messages onto the J1939 network. As shipped from the factory, the J2K100 only listens for J1939 messages and creates no bus traffic on the J1939 network. The J2K100 does however acknowledge received messages, which...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=304</guid>
										<title>Is the J2K100 compatible with Northern Lights Generators? If so, which ones?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=304</link>
										<description><![CDATA[The J2K100 will convert most J1939 messages that engine manufacturers provide. Northern Lights Gensets 65kw and above output the J1939 protocol which the J2K100 will convert.Please review the J2K100 User's Manual&nbsp; for detail of Genset messages.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=258</guid>
										<title>If I use the J2K100 with my Onan generator that has a power rating between 40-99kW, what data can I expect to see on the NMEA 2000 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=258</link>
										<description><![CDATA[The J2K100 provides the following information when hooked to an Onan generator with a power rating of 40-99 kW: Generator Average Line-Neutral AC RMS Voltage Generator Average AC RMS Frequency Engine Coolant Temperature Engine Oil Pressure Battery...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=244</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;NMEA 2000 Engine Instance:&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=244</link>
										<description><![CDATA[Maretron's DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 Engine Instance:" which is used to program the J2K100 to transmit the appropriate NMEA 2000 instance. For example, if the J2K100 is connected to the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=262</guid>
										<title>What are the approximate dimensions of the J2K100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=262</link>
										<description><![CDATA[The J2K100 measures aproximately 3" length, 3.5" width, and 1.5" tall (8cm length, 9cm width, and 4cm tall).
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=242</guid>
										<title>I see that Maretron`s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called &quot;J1939 Source Address:&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=242</link>
										<description><![CDATA[Maretron's DSM150,&nbsp; DSM200, and DSM250 displays have a J2K100 configuration setting called "J1939 Source Address:", which is used to program the J2K100 to accept only messages from a certain J1939 device. For example, there might be several...]]></description>

									</item>

</channel>

</rss>