<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Navigation Instruments  - RAA100  </title>
<link>https://maretron.com/wp-content/phpkbv96/category.php?id=18</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB (https://www.phpkb.com)</description>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=468</guid>
										<title>What type of information can be viewed on Maretron`s display products, and what products are required to generate the data to be displayed?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=468</link>
										<description><![CDATA[The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder.&nbsp; To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=439</guid>
										<title>What are the voltage specifications for each Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=439</link>
										<description><![CDATA[Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface CLM100 P/N: M000070&nbsp; Current Loop Monitor 9 to 32 Volts &nbsp; SSC200 P/N: M000001, M000021, M000022 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts &nbsp;...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=613</guid>
										<title>Can Maretron devices be displayed on a Raymarine Seatalk NG network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=613</link>
										<description><![CDATA[Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=374</guid>
										<title>Using N2KAnalyzer, how do I recover  a Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=374</link>
										<description><![CDATA[Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems. A Maretron device that is&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=673</guid>
										<title>Can Maretron`s sensor data be displayed on a Garmin network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=673</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Garmin displays with &ldquo;NMEA 2000&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=672</guid>
										<title>Can Maretron`s sensor data be displayed on a Furuno CANBUS network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=672</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Furuno displays with &ldquo;CANBUS&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp;specifically,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=271</guid>
										<title>How do I display the RAA100 rudder angle on Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=271</link>
										<description><![CDATA[You display the RAA100 rudder angle on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the rudder angle and press...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=273</guid>
										<title>How do I set the RAA100 rudder number or instance using Maretron`s DSM150, DSM200, or DSM250 display? </title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=273</link>
										<description><![CDATA[You set the RAA100 rudder number or instance using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter. Scroll...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=272</guid>
										<title>Why I can`t find a RAA100 rudder angle for display on Maretron`s DSM150, DSM200, or DSM250?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=272</link>
										<description><![CDATA[In order to keep the number of Maretron DSM150, DSM200, and DSM250 display menu items to a minimum (there is a possibility of more than 250 batteries, more than 250 engines, more than 250 rudders, etc.), the displays default to only a single rudder....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=281</guid>
										<title>Can I set the RAA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=281</link>
										<description><![CDATA[Yes, it is possible to set the RAA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=289</guid>
										<title>Why doesn`t my rudder display read hard over when the rudder is hard over?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=289</link>
										<description><![CDATA[The rudder display may not read hard over even though the rudder is hard over if the resistive sensor is not turning throughout its entire range. You can fix this by either adjusting the resistive sensor to turn across its entire range or you can...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=278</guid>
										<title>How do I set the RAA100 configuration setting called &quot;Gauge Resistance, - to sender&quot; using Maretron`s DSM150, DSM200, or DSM250 display? </title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=278</link>
										<description><![CDATA[You set the RAA100 "Gauge Resistance, - to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=279</guid>
										<title>What is the default calibration setting for the RAA100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=279</link>
										<description><![CDATA[The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboard). This can be changed using Maretron's DSM150,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=277</guid>
										<title>How do I set the RAA100 configuration setting called &quot;Gauge Resistance, + to sender&quot; using Maretron`s DSM150, DSM200, or DSM250 display? </title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=277</link>
										<description><![CDATA[You set the RAA100 "Gauge Resistance, + to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=283</guid>
										<title>Is it possible to turn on or off RAA100 transmitted messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=283</link>
										<description><![CDATA[Yes, it is possible to turn on and off the RAA100 transmitted messages (or PGNs) using Mareton's DSM150, DSM200, or DSM250 display. On the display, enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=284</guid>
										<title>How do I reset the RAA100 to send the factory default messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=284</link>
										<description><![CDATA[You reset the RAA100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter. Scroll...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=280</guid>
										<title>Can I set the RAA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron`s DSM150, DSM200, or DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=280</link>
										<description><![CDATA[Yes, it is possible to set the RAA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=268</guid>
										<title>What is an RAA100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=268</link>
										<description><![CDATA[The RAA100 is a rudder angle adapter that converts an analog resistive sender into digital information, which is then broadcast over the NMEA 2000 where any NMEA 2000 compatible display can show the rudder angle. The RAA100 can be used with or...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=292</guid>
										<title>How much power does the RAA100 consume?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=292</link>
										<description><![CDATA[The RAA100 draws less than 100mA (LEN=2) of current from the NMEA 2000 network at 12 volts, or 1.2 watts of power.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=269</guid>
										<title>What information does the RAA100 provide?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=269</link>
										<description><![CDATA[The RAA100 provides the the rudder angle.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=270</guid>
										<title>What messages (or PGNs) does the RAA100 transmit?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=270</link>
										<description><![CDATA[The RAA100 transmits the following message (or PGN): PGN 127245 - Rudder (Fields: 5 - Position) 
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=275</guid>
										<title>How do I set the RAA100 operating mode using Maretron`s DSM150, DSM200, or DSM250 display? </title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=275</link>
										<description><![CDATA[You set the RAA100 operating mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter. Scroll to the row...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=421</guid>
										<title>What firmware changes have taken place on the Maretron RAA100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=421</link>
										<description><![CDATA[...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=282</guid>
										<title>Can I custom calibrate the RAA100 for non-standard resistance sensors or can I do custom calibration for hard over points other than 60 degrees?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=282</link>
										<description><![CDATA[Yes, it is possible to calibrate the RAA100 to accept non-standard resistive sensors or to set custom hard over angles using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=290</guid>
										<title>Can I use the RAA100 if my hard over points are not 60 degrees?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=290</link>
										<description><![CDATA[Yes, you can use the RAA100 if the hard over points are not 60 degrees because the RAA100 can be custom calibrated for virtually any stop angle position. Hard over points can be calibrated over resistance values of 0 to 300 ohms.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=274</guid>
										<title>What is the RAA100 configuration setting &quot;operating mode&quot;?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=274</link>
										<description><![CDATA[The RAA100 can operate in one of two ways: without an analog gauge, which is referred to as the "NMEA 2000" mode, and with an analog gauge, which is referred to as the "NMEA 2000 &amp; Analog Gauge" mode The default mode of operation is without an...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=286</guid>
										<title>I know that the RAA100 uses resistive rudder angle sensors; who manufactures resistive sensors?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=286</link>
										<description><![CDATA[The RAA100 is compatible with resistive rudder style sending unit. The brand, VDO manufacturers a sensor (Figure#1) that can output 10-180&Omega; of resistance range. Simply connect the RAA100's white and black wires to the VDO sender's positive...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=276</guid>
										<title>What is the RAA100 configuration setting &quot;Gauge Resistance, + to sender&quot; and &quot;Gauge Resistance, - to sender&quot;?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=276</link>
										<description><![CDATA[If the RAA100's operating mode is set to "NMEA 2000 &amp; Analog Gauge", then it is important to configure the RAA100 with the gauge's resistances in order for the RAA100 to operate correctly. Please refer to the RAA100 User's Manual for a detailed...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=288</guid>
										<title>If the RAA100 is connected and configured to operate in the &quot;NMEA 2000 &amp; Analog Gauge&quot; mode, how do I connect the wires to the back of the analog gauge?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=288</link>
										<description><![CDATA[You connect the RAA100 operating in the "NMEA 2000 &amp; Analog Gauge" mode to the gauge in the following way: connect the black wire to the gauge ground terminal connect the green wire to the gauge sensor terminal connect the red wire to the gauge...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=287</guid>
										<title>If the RAA100 is connected and configured to operate in the &quot;NMEA 2000&quot; mode (i.e., without an analog gauge), how do I connect the wires to the resistive sensor?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=287</link>
										<description><![CDATA[You connect the RAA100 operating in the NMEA 2000 mode (i.e., without analog gauge) to a resistive sensor in the following way: connect the black wire to the sensor ground terminal connect the white wire to the sensor positive terminal 
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=291</guid>
										<title>How much electrical current does the RAA100 use?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=291</link>
										<description><![CDATA[The RAA100 draws less than 100mA (LEN=2) of current from the NMEA 2000 network.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=285</guid>
										<title>What type of rudder senders does the RAA100 work with?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=285</link>
										<description><![CDATA[The RAA100 works with resistive rudder angle senders (i.e., the resistance changes with rudder angle). In the U.S., the standard for resistive senders is 240 to 30 ohms where 240 ohms represents 60 degrees to port and 30 ohms represents 60 degrees to...]]></description>

									</item>

</channel>

</rss>