										<title>What type of information can be viewed on Maretron`s display products, and what products are required to generate the data to be displayed?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=468</link>
										<description><![CDATA[The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder.&nbsp; To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=439</guid>
										<title>What are the voltage specifications for each Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=439</link>
										<description><![CDATA[Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface CLM100 P/N: M000070&nbsp; Current Loop Monitor 9 to 32 Volts &nbsp; SSC200 P/N: M000001, M000021, M000022 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts &nbsp;...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=613</guid>
										<title>Can Maretron devices be displayed on a Raymarine Seatalk NG network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=613</link>
										<description><![CDATA[Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=374</guid>
										<title>Using N2KAnalyzer, how do I recover  a Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=374</link>
										<description><![CDATA[Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems. A Maretron device that is&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=673</guid>
										<title>Can Maretron`s sensor data be displayed on a Garmin network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=673</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Garmin displays with &ldquo;NMEA 2000&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=672</guid>
										<title>Can Maretron`s sensor data be displayed on a Furuno CANBUS network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=672</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Furuno displays with &ldquo;CANBUS&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp;specifically,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=583</guid>
										<title>What is the SMS100 Status message?  Which Maretron components do I need?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=583</link>
										<description><![CDATA[The SMS100 Status Message is a text message you can receive from the SMS100 containing key pieces of information regarding your vessel. When the SMS100 is installed, you can text the word&nbsp;"Status"&nbsp; to your&nbsp;SMS100 cellular number&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=538</guid>
										<title>What type of solderless connector is ideal for connecting sensor wire to Maretron multi-channel products?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=538</link>
										<description><![CDATA[A #4 Nylon Double-Crimp Insulated Ring Terminal(P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi channel devices. The following link provides a great color selection to choose from:  http://www.wiringproducts...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=343</guid>
										<title>How do I display the DC Time Remaining on the DSM150 or  DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=343</link>
										<description><![CDATA[You display the DC Time Remaining on the DSM150 or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press Enter. Scroll to the favorite screen where you would like to view the DC Time Remaining and press Enter....]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=403</guid>
										<title>What firmware changes have taken place on the Maretron DCM100 DC Monitor?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=403</link>
										<description><![CDATA[  Â  DCM100 Firmware Revisions Â  1.1.1.3 (2023-06-27)  Fix the watchdog reset in gen load default Correct response for testmode command "cal get" Added support for PGN 127751 (DC Voltage/Current) Added support for PGN 123993 (Heartbeat) Added...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=650</guid>
										<title>What configuration options are available for the DCM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=650</link>
										<description><![CDATA[Use the N2KAnalyzer software program or a Maretron DSM150, or Maretron DSM250 to perform Maretron Device level configuration. This article will show methods for configuring the DCM100 Using Maretron's N2KAnalyzer software tool.&nbsp; Pre-requisits:...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=338</guid>
										<title>What messages (or PGNs) does the DCM100 transmit?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=338</link>
										<description><![CDATA[The DCM100 transmits the following messages:
127506 DC Detailed Status: (DC Instance, DC Type, State of Charge, State of Health, Time Remaining, and Ripple Voltage. 
127508 Battery Status: (Battery Instance, Battery Voltage, Battery Current, Battery ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=336</guid>
										<title>Where would I use a DCM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=336</link>
										<description><![CDATA[You use the DCM100 if you have a Battery bank or a DC source network connection and you want to display DC bateries or DC electrical information on an NMEA 2000 compatible display.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=337</guid>
										<title>What information does the DCM100 provide over the NMEA 2000 network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=337</link>
										<description><![CDATA[The DCM100 can provide  Voltage, Power, Current, Battery Case Temperature, Time remaining, Ripple Voltage, State of health, and State of charge.  Review your NMEA 2000 Displays user manual to verify that above Items can be viewed.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=348</guid>
										<title>How do I set the DCM100 configuration setting called  &quot;Instance:&quot; using Maretron`s  DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=348</link>
										<description><![CDATA[You set the DSM100 configuration setting called " Instance:" using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter. Scroll to...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=335</guid>
										<title>What is a DCM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=335</link>
										<description><![CDATA[Maretron's DCM100 is a device which monitors DC power sources or batteries and outputs information about these sources onto the industry standard NMEA 2000&reg; marine data network.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=340</guid>
										<title>How do I display DC Voltage on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=340</link>
										<description><![CDATA[You display the DC Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Voltage and press enter. Scroll to "Data:" and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=342</guid>
										<title>How do I display the DC Ripple Voltage on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=342</link>
										<description><![CDATA[You display the DC Ripple Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Ripple Voltage and press enter. Scroll to ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=351</guid>
										<title>I see that Maretron`s DSM250 displays have a DCM100 configuration setting called &quot;Reset Factory Defaults&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=351</link>
										<description><![CDATA[Maretron's DSM250 displays have a DCM100 configuration setting called "Reset Factory Defaults", which is used to return the DCM100 to its factory settings. Resetting the DCM100 sets the NMEA 2000 instance back to 0 and returns PGN enable/disable back...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=552</guid>
										<title>Does Maretron offer a quick setup guide for the DCM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=552</link>
										<description><![CDATA[Configuring the DCM100 using the DSM150 or DSM250 display.Perform a current sensor zero offset with the current sensor attached to the DCM100. Step two: Scroll to DC Type and input the DC battery configuration:Configuring the DCM100 using the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=350</guid>
										<title>Is it possible to turn on or off DCM100 NMEA 2000 transmitted messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=350</link>
										<description><![CDATA[Yes, it is possible to turn on and off the DCM100 transmitted messages (or PGNs) using Maretron's DSM250 display. On the display, enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=346</guid>
										<title>How do I display the DC State of Charge on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=346</link>
										<description><![CDATA[You display the DC State of Charge  on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC State of Charge and press enter. Scroll...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=565</guid>
										<title>What are the dimensions of the DCM100 current transducers?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=565</link>
										<description><![CDATA[The DCM100 is packaged with a Hall Effect&nbsp;sensor (P/N: LEMHTA200-S) which is rated to measure currents up to 200 Amperes. If your application requires measurements exceeding 200 Amperes, &nbsp;Maretron offers additional sensors: 400 Amperes...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=312</guid>
										<title>With regards to the DCM100, where should I connect the ring terminal of temperature sensor (part number TR3K)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=312</link>
										<description><![CDATA[ You should connect the ring terminal on the Temperature Sensor to the negative terminal of the DC source being monitored.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=347</guid>
										<title>I see that Maretron`s DSM150 and DSM250 displays have a DCM100 configuration setting called &quot;Instance:&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=347</link>
										<description><![CDATA[Maretron's DSM150 and DSM250 displays have a DCM100 configuration setting called "Instance:", which is used to program the DCM100 to transmit the appropriate NMEA 2000 instance. For example, if the DCM100 is connected to a DC source, then this...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=344</guid>
										<title>How do I display the DC State of Health on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=344</link>
										<description><![CDATA[You display the DC State of Health on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC State of Health  and press enter. Scroll...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=352</guid>
										<title>How do I reset the DCM100 to send the factory default NMEA 2000 messages (or PGNs)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=352</link>
										<description><![CDATA[You reset the DCM100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration&hellip;" and press enter. Scroll to "Device Configuration&hellip;" and press enter. Scroll...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=349</guid>
										<title>I see that Maretron`s DSM150 and DSM250 displays have a DCM100 configuration setting called &quot;NMEA 2000 PGN Enable/Disable...&quot;; what is this?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=349</link>
										<description><![CDATA[Maretron's DSM150 and DSM250 displays have a DCM100 configuration setting called "NMEA 2000 PGN Enable/Disable&hellip;", which is used to turn on and off specific messages that are transmitted by the DCM100.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=339</guid>
										<title>How do I display DC Current on the Maretron`s  DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=339</link>
										<description><![CDATA[You display the DC Current on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC current and press enter. Scroll to "Data:" and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=311</guid>
										<title>What features does the DC/Battery Monitor (DCM100) have?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=311</link>
										<description><![CDATA[The Maretron DCM100 has the following features. NMEA 2000&reg; Interface Waterproof Connectors Sealed Waterproof Enclosure Opto-Isolated from NMEA 2000&reg; Eliminating Potential Ground Loops Can monitor DC Power Sources, Transmitting Voltage and...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=341</guid>
										<title>How do I display the DC Power on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=341</link>
										<description><![CDATA[You display the DC Power on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Power and press enter. Scroll to "Data:" and press...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=487</guid>
										<title>What is the maximum voltage the DCM100 can sense?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=487</link>
										<description><![CDATA[The DCM100 can sense voltages up to 50VDC on terminals 5 and 6.The maximum voltage that can be supplied to power the DCM100 on is 32VDC on terminals 7 and 8.   Pin Number   Signal Name   Connection   1   IA   Current Sensor, Red Wire   2   IB  ...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=345</guid>
										<title>How do I display the DC Temperature on the DSM250 display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=345</link>
										<description><![CDATA[You display the DC Temperature on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Temperature and press enter. Scroll to "Data:"...]]></description>
