<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=468</guid>
										<title>What type of information can be viewed on Maretron`s display products, and what products are required to generate the data to be displayed?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=468</link>
										<description><![CDATA[The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder.&nbsp; To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=439</guid>
										<title>What are the voltage specifications for each Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=439</link>
										<description><![CDATA[Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface CLM100 P/N: M000070&nbsp; Current Loop Monitor 9 to 32 Volts &nbsp; SSC200 P/N: M000001, M000021, M000022 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts &nbsp;...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=613</guid>
										<title>Can Maretron devices be displayed on a Raymarine Seatalk NG network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=613</link>
										<description><![CDATA[Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=374</guid>
										<title>Using N2KAnalyzer, how do I recover  a Maretron device?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=374</link>
										<description><![CDATA[Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems. A Maretron device that is&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=578</guid>
										<title>How do I monitor the bilge with Maretron equipment?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=578</link>
										<description><![CDATA[Before we discuss how to monitor the bilge with Maretron equipment, let's take a look at a typical bilge pump and alarm wiring diagram (see Figure 1). Notice that there are two ways to turn the bilge pump on. First, there is the float switch -- when...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=672</guid>
										<title>Can Maretron`s sensor data be displayed on a Furuno CANBUS network?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=672</link>
										<description><![CDATA[Yes, much of Maretron device's data can be shown on Furuno displays with &ldquo;CANBUS&rdquo; functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the&nbsp;Maretron product's datasheet&nbsp;specifically,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=583</guid>
										<title>What is the SMS100 Status message?  Which Maretron components do I need?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=583</link>
										<description><![CDATA[The SMS100 Status Message is a text message you can receive from the SMS100 containing key pieces of information regarding your vessel. When the SMS100 is installed, you can text the word&nbsp;"Status"&nbsp; to your&nbsp;SMS100 cellular number&nbsp...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=579</guid>
										<title>How do I show simple bilge information on Mareton`s DSM150 or DSM250 displays?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=579</link>
										<description><![CDATA[Knowldege base article 578 showed how to do simple bilge monitoring using Maretron's Run Indicator Module (RIM100). This article shows how the monitored information from article 578 can be displayed on Maretron's DSM150 and DSM250 displays. The left...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=615</guid>
										<title>I see N2KView offers a component for &quot;Indicator Status&quot;; what products can I use to show Indicator Status?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=615</link>
										<description><![CDATA[An Indicator Status component uses the NMEA 2000 message called "Binary Switch Bank Status" to show three condition states: On Off Error A RIM100, SIM100, and DCR100 all transmit the necessary message for the N2KView component to work. You can create...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=538</guid>
										<title>What type of solderless connector is ideal for connecting sensor wire to Maretron multi-channel products?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=538</link>
										<description><![CDATA[A #4 Nylon Double-Crimp Insulated Ring Terminal(P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi channel devices. The following link provides a great color selection to choose from:  http://www.wiringproducts...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=542</guid>
										<title>Helpful information regarding Smoke/Heat Detector - SH-449CSTE</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=542</link>
										<description><![CDATA[Installation notes:Smoke detectors are shipped with a plastic dust cover for use in areas where construction is on-going. Smoke detectors will not workwith the dust cover in place. Remove the dust cover when installation is completed, prior to...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=617</guid>
										<title>Does Maretron offer a Quick Setup guide for the SIM100 using N2KAnalyzer?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=617</link>
										<description><![CDATA[Maretron's Switch Indicator Module monitors dry contacts. Once you have selected the dry contact device, connect the two leads from the device to&nbsp;one of six&nbsp;SIM100 channels. Each channel has two terminals; for example, Channel #0 uses...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=534</guid>
										<title>Smoke Alarms – Why don`t we use them on boats?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=534</link>
										<description><![CDATA[&nbsp;  Please see attached white paper written by Captain John McDevitt regarding why smoke alarms aren't mandated on boats, but why they should be. Maretron smoke and heat vessel monitoring system designed with N2KBuilder.  &nbsp;
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=363</guid>
										<title>How do I display a SIM100 channel on the Maretron DSM250?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=363</link>
										<description><![CDATA[&nbsp; You display a SIM100 channel using the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup&hellip;" and press enter. Scroll to the favorite screen where you would like to view the indicator channel*.* and press enter...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=364</guid>
										<title>How do I configure a channel on the SIM100 using Maretron`s DSM250 Display?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=364</link>
										<description><![CDATA[&nbsp; You configure a channel on the SIM100 in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row containing SIM100 and press enter. Select instance...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=432</guid>
										<title>What does Maretron recommend for the mounting of the Bilge High Water (BHW100) sensor?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=432</link>
										<description><![CDATA[&nbsp; &nbsp; &nbsp;  The BHW100 sensor has a etched target molded into the plastic enclosure (located opposite of the side with&nbsp;a Maretron label). The target should be exposed to the area of detection&nbsp;to monitor&nbsp;water ingress in...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=446</guid>
										<title>Can I use the SIM100 to tell whether a bulb is burnt out?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=446</link>
										<description><![CDATA[Yes, you can use the SIM100 together with a CR Magnetics current sensing relay to indicate that a bulb is burnt out. There are many different available configurations of the current sensing relay, but part numbers that have been tested with the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=485</guid>
										<title>How much current does the Maretron Smoke/Heat Detector (part # SH-002) draw from a power source?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=485</link>
										<description><![CDATA[...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=422</guid>
										<title>What firmware changes have taken place on the Maretron SIM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=422</link>
										<description><![CDATA[What firmware changes have taken place on the Maretron SIM100? Update your device using the&nbsp;N2KAnalyzer&nbsp;software tool. &nbsp; SIM100 Firmware Versions &nbsp; 1.2.2.2 (2015-08-29) Ensured that PGN 127501 is transmitted immediately when the...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=356</guid>
										<title>What is the SIM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=356</link>
										<description><![CDATA[The SIM100 is a device that allows the N2K user to monitor up to six of any type of dry contacts.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=310</guid>
										<title>What is the purpose of the Switch Indicator Module (SIM100)?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=310</link>
										<description><![CDATA[The SIM100's purpose is to deliver switch status over an NMEA 2000&nbsp;network. Because of this feature, the use of common end of line components is available. The most common of such components are normally closed switches, such as magnetic door,...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=455</guid>
										<title>Can I use the SIM100 to monitor Carbon Monoxide (CO) detectors?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=455</link>
										<description><![CDATA[Yes, you can use the SIM100 to monitor Carbon Monoxide (CO) detectors as long as the detector has an auxiliary contact. Maretron offers a CO detector ( https://www.maretron.com/support/manuals/CO-CO1224T%20Installation%20Instructions%201.1.html ) The...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=308</guid>
										<title>What PGN`s does the SIM100 transmit?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=308</link>
										<description><![CDATA[The SIM100 will transmit PGN 127501 (Fields: 1-SID, 2 through 28-Switch status) 
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=381</guid>
										<title>How many channels are available on the SIM100?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=381</link>
										<description><![CDATA[The SIM100 has six available channels for use with two types of switches.Please refer to to the SIM100 manual for specifications on these two types of switches.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=484</guid>
										<title>Does the gas detector (Maretron part LP-200012UL) have a power supervision relay?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=484</link>
										<description><![CDATA[Although some of Maretron's SIM100 accessories have built-in power supervision relays like the smoke/heat detector (Maretron part number SH-002) and carbon monoxide detector (Maretron part number CO-CO1224T), the gas detector does not have a built in...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=508</guid>
										<title>What are the dimensions of the SIM100 accessory magnetic sensors?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=508</link>
										<description><![CDATA[&nbsp;Please see the attached data sheets for the magnetic sensor dimensions.
]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=483</guid>
										<title>I see that some of Maretron`s SIM100 accessories have built in “trouble relays”; what is a trouble relay and why is it important?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=483</link>
										<description><![CDATA[Trouble relays are being integrated into more and more safety and security equipment to provide added safety and security features. For example, a trouble relay can act as power supervision device. In this case, if the power is accidentally turned...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=408</guid>
										<title>How can I tell whether a navigation light is working when I have turned it on?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=408</link>
										<description><![CDATA[The Maretron development team has found this particular device which can monitor current through a wire. This is especially usefull dermining if in fact a vessel's light is turned on and not burned out. There are two variants of this device for AC...]]></description>

									</item>
<item>
										<guid>https://maretron.com/wp-content/phpkbv96/article.php?id=562</guid>
										<title>Does Maretron recomend a particular propane and gas leak detector?</title>
										<link>https://maretron.com/wp-content/phpkbv96/article.php?id=562</link>
										<description><![CDATA[Maretron does not recommend a particular brand propane/gas detector.  The only requirement for a chosen detector is a NO/NC relay output for the device to monitored with a SIM100.  Many detectors offer several options when connecting to an input...]]></description>
